ReluxEnergyCH  

Step 4: Room book

Learn how to create panoramic pictures through the real-time rendering function in ReluxDesktop.

All the rooms in the building are captured in the room book and typical rooms allocated as per  step 2 , and luminaire types allocated as described in  step 3 .

Any desired designation can be selected for the  Name  (name),  Raumnummer  (room number) and  Stockwerk  (storey).


For each room, the spezifische  Leistung  (specific power) and the  Projekt-  (project) and

Anforderungswertwert  (specified value) – as per the selection in  step 1 : SIA -Limit Value,  SIA -Target Value, MINERGIE® or Effeled – in kWh/m² are calculated automatically.

The red or green dot in the first column shows whether the requirement is met for the room or not.


In our case, there is a need for optimisation in  Raum 1  (room 1) and  Raum 4  (room 4).

Go back to step 2 Typische Räume (Form 2, Typical rooms).



Using a contemporary lighting control system, the absolute electricity consumption of the lighting installation can be aligned to the conditions of use and the daylight conditions. 

Select:

  1. Tageslichtregelung: Konstantlicht (Daylight control system: constant light)
  2. Präsenzmelder: auto off (Presence detector: auto off)


Back in the room book, it is clear that the  Minergie Anforderungswertwert  (requirement value) is not exceeded in any of the rooms.

Video Resources  

Realtime Rendering - Screen Capture

 
 

Still questions?  

Contact Support

Thank you for your
Support request!

Our team will message you back as soon as possible.
In the meantime we invite you to browse further in our Knowledge DB.


More  

Related Topics


Title

Subtitle

Title

Subtitle

Title

Subtitle